NEC×Fire Protection

NEC Fire Protection Compliance Check

AI-powered National Electrical Code (NFPA 70) compliance checking for fire protection construction drawings. Detect violations, missing requirements, and code compliance issues before they delay your permit or hit the field.

About National Electrical Code (NFPA 70)

The US standard for electrical installations including wiring, overcurrent protection, grounding, and equipment. Adopted by most jurisdictions as the basis for electrical code enforcement.

Scope

Electrical installations in all building types

Editions

2023 NEC, 2020, 2017, 2014

Applicability

Adopted in nearly all US jurisdictions. Some states lag by one or two editions.

What We Check For

NEC compliance checking for fire protection drawings
Cross-reference fire protection details against National Electrical Code (NFPA 70) requirements
Verify fire protection specifications meet NEC minimum standards
Check fire protection coordination against NEC referenced standards
Identify fire protection issues that could cause NEC compliance failures
Review fire protection drawings for common NEC violations

Common Fire Protection Issues We Catch

Fire sprinkler, standpipe, fire alarm, and smoke control drawings.

!
Sprinkler head spacing and obstruction violations
!
Missing sprinkler coverage in concealed spaces
!
Standpipe hose connection location errors
!
Fire department connection (FDC) access and signage
!
Smoke detector spacing exceeding maximums
!
Fire barrier penetration sealing omissions
!
Hydraulic calculation errors for water supply

Why NEC Fire Protection Compliance Matters

National Electrical Code (NFPA 70) compliance for fire protection drawings is critical because violations discovered during plan review delay permits, and issues found during construction result in costly rework, change orders, and schedule delays. Catching NEC fire protection issues during preconstruction costs 10x less than fixing them in the field (CII, 1-10-100 Rule).

How Articulate Checks NEC Compliance

1

Upload Your PDF Drawings

Upload your fire protection PDF drawings. No BIM models or 3D software required — Articulate works with the 2D PDFs your team already uses.

2

Purpose-Built Construction AI

Articulate's AI is trained specifically to review construction drawings against NEC requirements. Domain-specific training catches issues that generic AI tools miss.

3

Exact Issue Locations

Every NEC compliance issue is tagged with the exact page and coordinates on your drawings, plus severity ratings (high, medium, low) so you can prioritize.

4

One-Click RFI Generation

Turn detected NEC issues into formatted RFIs with a single click. Push directly to Procore with issue details, code references, and page locations.

Related Resources

NEC Checks for Other Disciplines

Fire Protection Checks Against Other Codes

Check Your Fire Protection Drawings Against NEC

Upload your PDF drawings and our AI will check them for National Electrical Code (NFPA 70) compliance — automatically.