Vertical Alignment & Stacking
Multi-Floor Coordination
Verify vertical alignment of plumbing risers, shafts, columns, and walls across floors. Articulate cross-references every floor plan in a multi-story building to catch misalignments that cause structural issues, plumbing rework, and costly field coordination.
Why Stacking Analysis Matters
How It Works
- 1
Map Each Floor
The AI reads every floor plan to identify columns, shaft walls, plumbing risers, stairwells, elevator shafts, and structural walls, mapping their exact positions relative to the grid.
- 2
Establish Grid Baseline
Column grid lines are established as the reference framework. Every vertical element is located relative to the grid to create a consistent coordinate system across floors.
- 3
Compare Floor-to-Floor
The system overlays each floor with the floor above and below, checking that every vertical element maintains its position, size, and orientation as it passes through each level.
- 4
Flag Misalignments
Any element that shifts, grows, shrinks, or disappears between floors is flagged with exact measurements showing the offset and the affected floor levels.
Key Capabilities
Column Alignment Verification
Checks that structural columns maintain their grid positions across all floors, catching offsets that may indicate drafting errors or uncoordinated design changes between structural and architectural plans.
Plumbing Riser Stacking
Verifies that waste, vent, and water risers align vertically from floor to floor, ensuring that the plumbing chase on each level connects properly without requiring horizontal offsets in the slab.
Shaft Wall Continuity
Traces mechanical, electrical, and plumbing shaft walls through every floor, confirming that shaft dimensions remain consistent and that fire-rated shaft enclosures are continuous.
Stairwell Consistency
Compares stair geometry across floors to verify that tread/riser counts, landing positions, and stair widths are consistent, catching errors that would result in code violations or fit-up issues.
Elevator Shaft Alignment
Verifies that elevator hoistway dimensions, door openings, and shaft wall positions are identical on every floor, as even small deviations can prevent elevator installation.
Load-Bearing Wall Stacking
Checks that load-bearing walls shown on structural plans align with architectural partitions floor-to-floor, catching cases where architectural changes weren't coordinated with the structural engineer.
Why This Matters
In multi-story buildings, vertical elements must stack precisely. A plumbing riser that shifts even 6 inches between floors requires a horizontal offset in the slab — which means a larger slab penetration, potential conflicts with post-tension cables, and coordination with the structural engineer. A shaft wall that changes size means the fire-rated enclosure has a gap that won't pass inspection.
These misalignments are hard to catch in manual review because each floor plan is typically reviewed independently. Articulate systematically compares every floor to every adjacent floor, catching the subtle shifts that accumulate across a 20-story building and surface as major problems during construction.
Related
See Stacking Analysis in Action
Upload your multi-floor plans to see how our AI catches vertical misalignments across levels.